IMS2025 Exhibition Hours: Tuesday,17 June 2025 09:30-17:00Wednes

Product

  • 4×4 LDQ-0.698/3.8-N 4X4 Hybrid Coupler

    4×4 LDQ-0.698/3.8-N 4X4 Hybrid Coupler

    Type:4×4 LDQ-698/3800-N

    Frequency:698-3800Mhz

    Insertion Loss:7.2dB

    Amplitude Balance:±0.6dB

    Phase Balance: ±5

    VSWR: ≤1.30: 1

    Isolation:≥20dB

    Connecter:N-F or 4.3-10

    PIM(IM3):<-150dBc@2×+43dBm

    Power: 300W

    Operating Temperature Range:-40˚C ~+85˚C

    Outline:Unit: mm

  • 700-2700Mhz 3dB Hybrid Coupler

    700-2700Mhz 3dB Hybrid Coupler

     

    Type:LDQ-0.7/2.7-3dB-3NA                                          Frequency:0.7-2.7Ghz

    Insertion Loss:3dB                                                           Amplitude Balance:±0.6dB

    VSWR: ≤1.3: 1                                                                   Isolation:≥20dB

    Power: 200W                                                                       PIM 3:≤-150dBc @(+43dBm×2)

    Connecter:N-F                                Operating Temperature Range:-40˚C ~+85˚C

     

  • 0.8-12Ghz LDC-0.8/12-180S 180 degree hybrid coupler

    0.8-12Ghz LDC-0.8/12-180S 180 degree hybrid coupler

    Type:LDC-0.8/12-180S                                   Frequency:0.8-18 Ghz

    Insertion Loss:4.5dB                                       Amplitude Balance:±1.5dB

    Phase Balance: ±15                                          VSWR: ≤1.65: 1

    Isolation:≥15dB                                                Connecter:SMA-F

    Power: 50W                                                      Operating Temperature Range:-35˚C ~+85˚C

  • LDC-0.8/18-180S 0.8-18 Ghz 180 Degree Hybrid Coupler

    LDC-0.8/18-180S 0.8-18 Ghz 180 Degree Hybrid Coupler

    Type:LDC-0.8/18-180S

    Frequency:0.8-18 Ghz

    Insertion Loss:4.5dB

    Amplitude Balance:±1.5dB

    Phase Balance: ±15

    VSWR: ≤1.65: 1

    Isolation:≥15dB

    Connecter:SMA-F

    Power: 50W

    Operating Temperature Range:-35˚C ~+85˚C

    Outline:Unit: mm

  • LDC-1/2-180S L band 180 Degree hybrid coupler

    LDC-1/2-180S L band 180 Degree hybrid coupler

    Type:LDC-1/2-180S                                                         Frequency:1-2Ghz

    Insertion Loss:0.5dB                                                       Amplitude Balance:±0.7dB

    Phase Balance: ±8                                                           VSWR: ≤1.35: 1

    Isolation:≥20dB                                                               Connecter:SMA-F

    Power: 20W                                                                      Operating Temperature :-40˚C ~+85˚C

  • LDC-1/6-180S 1-6Ghz 180° Hybrid Coupler

    LDC-1/6-180S 1-6Ghz 180° Hybrid Coupler

    Type:LDC-1/6-180S

    Frequency:1-6Ghz

    Insertion Loss:1.8dB

    Amplitude Balance:±0.7dB

    Phase Balance: ±7

    VSWR: ≤1.6: 1

    Isolation:≥17dB

    Connecter:SMA-F

    Power: 50W

    Operating Temperature Range:-40˚C ~+85˚C

    Outline:Unit: mm

  • LDC-2/2.2-6dB-S 2 In 4 Out Hybrid Coupler

    LDC-2/2.2-6dB-S 2 In 4 Out Hybrid Coupler

    Type:LDC-2/2.2-6dB-S

    Frequency:2-2.2Ghz

    Insertion Loss:0.6dB

    Amplitude Balance:±0.35dB

    Phase Balance: ±5

    VSWR: ≤1.25: 1

    Isolation:≥20dB

    Connecter:SMA-F

    Power:10W

    Operating Temperature Range:-20˚C ~+65˚C

    Outline:Unit: mm

  • 2-18G 90 degree hybrid coupler

    2-18G 90 degree hybrid coupler

    Type:LDC-2/18-90s

    Frequency:2-18Ghz

    Insertion Loss:1.6dB

    Phase Balance: ±3

    Amplitude Balance:±0.7

    Isolation :15

    connecter:sma

  • LDC-2/18-180S 2-18Ghz 180 Degree Hybrid splitter coupler

    LDC-2/18-180S 2-18Ghz 180 Degree Hybrid splitter coupler

    Type:LDC-2/18-180S                                                Frequency:2-18Ghz

    Insertion Loss:2.0dB                                                Amplitude Balance:±0.6dB

    Phase Balance: ±10                                                   VSWR: ≤1.6: 1

    Isolation:≥16dB                                                         Connecter:SMA-F

    Power: 20W                                                               Operating Temperature :-40˚C ~+85˚C

  • LDC-4/10-90N Hybrid Combiner With Low phase and amplitude unbalance

    LDC-4/10-90N Hybrid Combiner With Low phase and amplitude unbalance

    Type:LDC-4/10-90N

    Frequency:4-10Ghz

    Insertion Loss:1.0dB

    Amplitude Balance:±0.7dB

    Phase Balance: ±4

    VSWR: ≤1.4: 1

    Isolation:≥17dB

    Connecter:N-F

    Power: 50W

    Operating Temperature Range:-40˚C ~+85˚C

    Outline:Unit: mm

  • LDC-5/50-90S 50Ghz 90degree hybrid combiner

    LDC-5/50-90S 50Ghz 90degree hybrid combiner

    Type:LDC-5/50-90S                                             Frequency:5-50Ghz

    Insertion Loss:2.8dB                                            Amplitude Balance:±1.4dB

    Phase Balance: ±10                                               VSWR: ≤2.1: 1

    Isolation:≥11dB                                                     Connecter:2.4-F

    Power: 5W                                                             Impedance:50 OHMS

    Operating Temperature Range:-40˚C ~+85˚C

     

  • LDC-6/18-90S 90 degree hybrid combiner with SMA connecter

    LDC-6/18-90S 90 degree hybrid combiner with SMA connecter

    Type:LDC-6/18-90S                                                Frequency:6-18Ghz

    Insertion Loss:0.75dB                                            Amplitude Balance:±1dB

    Phase Balance: ±5                                                 VSWR: ≤1.6: 1

    Isolation:≥15dB                                                     Connecter:SMA-F